Transair Air Pipe Systems
|
The innovative technology of Transair enables rapid and easy assembly with quick connection of components to the aluminum pipe. Pipe and fittings are supplied ready for immediate installation so there is no preparation required. This technology takes into account the specific requirements of each diameter and provides the user with an optimum safety coefficient and easy connection. |
Quick Assembly Brackets
|
New generation quick assembly brackets are recommended for vertical or horizontal take-offs, using either rigid pipe or flexible hose.
- Integral water retention device
- Very high flow
- Quick installation without any cutting of pipe
|
Sizing Chart
| Flow Rate |
Length |
Compressor (hp) |
| 164ft |
328ft |
492ft |
984ft |
1640ft |
2460ft |
3280ft |
4265ft |
5249ft |
6561ft |
| Nm3/h |
NI/min |
cfm |
50m |
100m |
150m |
300m |
500m |
750m |
1000m |
1300m |
1600m |
2000m |
| 10 |
167 |
6 |
16.5 |
16.5 |
16.5 |
16.5 |
16.5 |
16.5 |
16.5 |
25 |
25 |
25 |
2-10 |
| 30 |
500 |
18 |
16.5 |
16.5 |
16.5 |
25 |
25 |
25 |
25 |
25 |
25 |
40 |
| 50 |
833 |
29 |
16.5 |
25 |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
40 |
10-40 |
| 70 |
1167 |
41 |
25 |
25 |
25 |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
| 100 |
1667 |
59 |
25 |
25 |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
63 |
| 150 |
2500 |
88 |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
63 |
63 |
63 |
| 250 |
4167 |
147 |
40 |
40 |
40 |
40 |
63 |
63 |
63 |
63 |
63 |
63 |
| 350 |
5833 |
206 |
40 |
40 |
40 |
63 |
63 |
63 |
63 |
63 |
63 |
76 |
| 500 |
8333 |
294 |
40 |
40 |
63 |
63 |
63 |
63 |
63 |
76 |
76 |
76 |
40-100 |
| 750 |
12500 |
441 |
40 |
63 |
63 |
63 |
63 |
76 |
76 |
76 |
76 |
100 |
| 1000 |
16667 |
589 |
63 |
63 |
63 |
63 |
63 |
76 |
76 |
100 |
100 |
100 |
| 1250 |
20833 |
736 |
63 |
63 |
63 |
63 |
63 |
100 |
100 |
100 |
100 |
100 |
100-425 |
| 1500 |
25000 |
883 |
63 |
63 |
63 |
76 |
76 |
100 |
100 |
100 |
100 |
100* |
| 1750 |
29167 |
1030 |
63 |
63 |
76 |
76 |
76 |
100 |
100 |
100 |
100* |
100* |
| 2000 |
33333 |
1177 |
63 |
76 |
76 |
76 |
100 |
100 |
100 |
100* |
100* |
100* |
| 2500 |
41667 |
1471 |
63 |
76 |
76 |
76 |
100 |
100* |
100* |
100* |
100* |
100* |
| 3000 |
50000 |
1766 |
76 |
76 |
76 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
| 3500 |
58333 |
2060 |
76 |
76 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
| 4000 |
66667 |
2354 |
76 |
100 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
425 |
| 4500 |
75000 |
2649 |
76 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
100* |
| 5000 |
83333 |
2943 |
76 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
100* |
| 5500 |
91667 |
3237 |
100 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
100* |
| 6000 |
100000 |
3531 |
100 |
100 |
100* |
100* |
100* |
100* |
100* |
100* |
100* |
100* |
| * Pressure drop > 5% |
|
For Example:
- Main network length (ring main): 984ft
- Compressor power: 40hp
- Required flow rate: 147cfm
- Working pressure: 115psi
- The most suitable Transair diameter is: 40
For more detailed information, download printable brochures now.
|